LNB93316 ROTHIUM CABLE

APPLICATION

Halogen-free, flexible cable, suitable for flexible andprotected installation in the interior for door control orin protecting tubes for outdoor laying at the bogie,railway machines or as connection cable between thewaggons. Appropriate for light and mediummechanical stress.

 

Outstanding feature

shalogen-free continuously flexible good EMCcharacteristics*no flame propagation flame retardantand self-extinguishinggood ozone and UVresistance good oil and fuel resistance good acid andalkalines resistance fulfils fire protection requirementsR15 (EL1A) and R16 (EL1B) acc. to EN 45545-2 forhazard levels HL1-2* (screened version)

Copper braiding should be * connected circularly tooptimize the EMC characteristics.

 

CABLE CONSTRUCTION

Conductor

Bare copper strands acc. to IEC 60228, EN 60228,VDE 0295, class 6

 

Insulation

special Polymer

 

Colour code

black cores with consecutive numbers acc. to EN50334;green-yellow earth wire from 3 cores.

Twisted pairs type without green-yellow earth wire

 

Stranding

In layers resp. pairwise

Wrapping:PP-foil

 

Screen

Tinned copper braiding (if existing)

 

Sheath material

rothium Ultra

 

Sheath color

Black

 

TECHNICAL DATA

Nominal voltage

Uo/U 300/500 V

 

Testing voltage2000 V

 

Min. bending radius

fixed laying unshielded 4 x d

fixed laying shielded 5 x d

flexible application unshielded 6 x d

flexible application shielded 10 x d

Continuously flexible unshielded: 12 x d

Continuously flexible shielded 15 x d

 

Temperature Range

fixed laying: -50/+90 °C

flexible application: -40/+90 °C

Halogen-free acc. to DIN EN 50306-1 + DIN EN 50264-1 are fulfilled.

 

Development of HCl is < 0,5%acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2 Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-Fluoric content < 0,1% acc. to DIN EN 60684-2

 

Fire performance

No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305section 9.1.2.

 

Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2.

 

Toxicity

acc. to DIN EN 50305

 

Smoke density

acc. to DIN EN 61034

Oil and fuel resistance

acc. to DIN EN 50264-1

 

Flexibility

very good

 

Absence of harmful substances

acc. to RoHS directive of the European Union